Retrofit-ready DC platform

Control Techniques DC Drive

A powerful, smart, and scalable platform to modernize existing DC motor lines.

Mentor MP integrates performance, flexibility, and service sustainability into a single platform for facilities looking to preserve classic DC motor infrastructure, high-current process lines, and Mentor II modernizations.

25 A – 7400 A
Armature current platform
400 / 575 / 690 V
Supply voltage classes
2Q / 4Q
Motoring and regeneration
5 Years
Standard warranty
Mentor MP DC

Engineering Perspective

Not just an ordinary DC drive, but a system built for years of trouble-free operation.

Unlike legacy DC drives, Mentor MP offers a fully digital, modular architecture that is completely compliant with the latest generation of automation standards.

Retrofit-focused architecture

Retains terminal and mounting layouts for Mentor II migrations, reducing conversion costs and commissioning risks.

Drive Intelligence

Brings automation capabilities into the drive with an on-board PLC, SyPTPro, and modular option structures.

Broad communication ecosystem

Enables easy integration with modern IT/OT networks via EtherCAT, PROFINET, PROFIBUS, Ethernet/IP, and additional feedback modules.

High power configuration

Provides a scalable platform approach for massive current requirements with parallel 6, 12, and 24 pulse topologies.

Video Gallery
Control Techniques Mentor MP
Engineering Decision Points

Internal Field Control

Includes an 8A internal field controller in Frame 1 devices, and 20A in Frame 2 devices. FXMP25 is required for higher currents.

Parallel Operation Note

Supports 6, 12, and 24 pulse parallel topologies. A 5% de-rating in armature current must be considered during parallel use.

Safety Note

Mentor MP does not have a built-in STO function. Safety architectures must be designed using external contactors and safety relays.

Control modes and core functions

Speed, torque, winder, field weakening, and closed-loop options

Estimated speed (open loop)
Tacho feedback (closed loop)
Encoder feedback (closed loop)
Speed control
Torque control
Torque + speed override
Winder mode
Field weakening / voltage control

Option modules

Fieldbus, I/O, feedback, and automation ecosystem

SM-EtherCAT SM-PROFINET SM-PROFIBUS SM-Ethernet SM-DeviceNET SM-CANopen SM-Interbus SM-I/O Plus SM-I/O Lite SM-Universal Encoder Plus SM-Applications Plus FXMP25

Frame and platform summary

Summary on-page, download center for detailed model datasheets.

Frame Current Range Supply Dimensions Engineering Note
1A 25 – 75 A 480 / 575 V 293 × 444 × 222 mm Compact field retrofits and medium-power DC motors.
1B 105 – 210 A 480 / 575 V 293 × 444 × 251 mm Standard process lines and revision projects.
2A 350 – 550 A 480 / 575 / 690 V 495 × 640 × 301 mm Applications requiring high current but limited panel space.
2B 700 – 900 A 480 / 575 / 690 V 495 × 640 × 301 mm Heavy processes, strong regen, and high torque demands.
2C / 2D 1200 – 1850 A 480 / 575 / 690 V 555 × 1050 × 611 mm Large DC machines, high power upgrades, and parallel system architectures.
Commissioning Ecosystem

The true power of Mentor MP lies not just in the drive, but in the tools that manage it.

CTSoft

The primary tool for commissioning, parameter management, cloning, and smartcard operations.

CTScope

Real-time oscilloscope for time-based monitoring of variables within the drive and tuning processes.

SyPTLite

Ladder-based internal user program editor for simple logic applications.

SyPTPro

Advanced automation programming environment supporting Function Block, Structured Text, and PLCopen motion.

Software & Document Center

Control Techniques Mentor MP Resource Center

Commissioning software, parameter guides, fieldbus files and CAD data — securely downloadable from a single place.

33
Toplam Dosya
19
Catalogs and Guides
7
Fieldbus and Communication
4
Software
3
3D CAD Models

Catalogs and Guides

Technical documents for Mentor MP drives, retrofit, field control and option modules.

19 dosya

Beckhoff IO User Guide

I/O

Reference document for using Mentor MP with Beckhoff-based I/O and communication infrastructure.

PDF 2.05 MB Beckhoff IO User Guide Issue 4 (0485-0019-04)_Approved.pdf

CTNet User Guide

Network

Reference guide for drive-to-drive communication and Control Techniques network architecture.

PDF 2.05 MB CTNet_User_Guide_Iss9 (0460-0025-09)_Approved.pdf

FXMP25 Field Controller Guide

Field Control

User guide for applications requiring external field current control up to 25 A.

PDF 1.04 MB FXMP-User-Guide.pdf

MP Keypad User Guide

Keypad

Installation and operating details for the optional LED keypad.

PDF 2.01 MB SM-Keypad-Plus-and-MP-Keypad-User-Guide-EN.pdf

SM EtherCAT User Guide EN

PDF

Downloadable technical file in PDF format.

PDF 1.96 MB SM-EtherCAT-User-Guide-EN.pdf

SM Ethernet User Guide EN

PDF

Downloadable technical file in PDF format.

PDF 2.84 MB SM-Ethernet-User-Guide-EN.pdf

SM PROFINET User Guide EN

PDF

Downloadable technical file in PDF format.

PDF 1.37 MB SM-PROFINET-User-Guide-EN.pdf

SM-Applications Plus User Guide

Automation

Option module documentation for on-drive PLC / motion applications.

PDF 1.89 MB SM-Applications-User-Guide-EN.pdf

SM-Encoder Plus Guide

Feedback

Documentation for the additional encoder feedback and encoder output module.

PDF 1.13 MB SM-Encoder-Plus-and-SM-Encoder-Output-Plus-User-Guide-EN.pdf

SM-I/O 32 User Guide

I/O

User guide for the additional digital / analog I/O expansion module.

PDF 1016.56 KB SM-IO-32-User-Guide-EN.pdf

SM-Register User Guide

Registers

Guide to register-based integration and parameter access.

PDF 2.13 MB SM-Register-User-Guide-EN.pdf

SM-Resolver Guide

Resolver

Installation and operating information for the resolver feedback module.

PDF 1.4 MB SM-Resolver-User-Guide-EN.pdf

SM-Universal Encoder Plus Guide

Feedback

Detailed user guide for the universal feedback interface module.

PDF 3 MB SM-Universal-Encoder-Plus-User-Guide-EN.pdf

Fieldbus and Communication

Files required for EtherCAT, PROFINET, PROFIBUS and network integration.

7 dosya

Beckhoff IO User Guide

I/O

Reference user guide for Beckhoff IO connection architecture.

PDF 2.05 MB Beckhoff IO User Guide Issue 4 (0485-0019-04)_Approved.pdf

CTNet User Guide

CTNet

Guide to CTNet communication infrastructure and network topologies.

PDF 2.05 MB CTNet_User_Guide_Iss9 (0460-0025-09)_Approved.pdf

SM-Ethernet User Guide

Ethernet

User guide for the Ethernet communication module.

PDF 2.84 MB SM-Ethernet-User-Guide-EN.pdf
Project-Specific Technical Assessment

Let's clarify your Mentor MP retrofit, power selection, and fieldbus architecture

Share your existing DC motor nameplate, field current, feedback type, and PLC / communication expectations. ONX Control engineers will recommend the optimal Mentor MP platform.

Most Critical Input
Motor nameplate + field current
If Retrofitting
Old drive model and panel size
Integration
PLC / SCADA / fieldbus preference

Cookie Preferences

We use essential cookies to run this site. Analytics and marketing cookies for visitor statistics and ad measurement are only used if you consent.

View Policy