Slot 4 Menu 0 − Ethernet Setup

Mode: RFC‑S

Setup parameter information


Parameter4.00.001  Module ID
Short descriptionModule ID
Minimum0Maximum65535
Default Units 
Type16 Bit VolatileUpdate RatePower-up
Display FormatStandardDecimal Places0
CodingRO, ND, NC, PT, BU

The Module ID. Onboard Ethernet module = 430. SI-Ethernet = 433. RR-Ethernet = 437


Parameter4.00.002  Software Version
Short descriptionSoftware Version
Minimum0Maximum99999999
Default Units 
Type32 Bit VolatileUpdate RatePower-up
Display FormatVersionDecimal Places0
CodingRO, ND, NC, PT

Module firmware version in ww.xx.yy.zz format


Parameter4.00.003  Hardware Version
Short descriptionHardware Version
Minimum0.00Maximum655.35
Default Units 
Type16 Bit VolatileUpdate RatePower-up
Display FormatStandardDecimal Places2
CodingRO, ND, NC, PT, BU

Contains the module’s hardware version information in the format xx.yy.


Parameter4.00.004  Serial Number LS
Short descriptionSerial Number LS
Minimum0
(Display: 00000000)
Maximum99999999
(Display: 99999999)
Default Units 
Type32 Bit VolatileUpdate RatePower-up write
Display FormatLead Zero PadDecimal Places0
CodingRO, ND, NC, PT

The module serial number is available as a pair of 32 bit values where Serial Number LS (MM.004) provides the least significant 8 decimal digits and Serial Number MS (MM.005) provides the most significant 8 decimal digits. The reconstructed serial number is ((MM.005* 100000000) + MM.004). For example serial number "0001234567898765" would be stored as MM.005 = 12345, MM.004 = 67898765.


Parameter4.00.005  Serial Number MS
Short descriptionSerial Number MS
Minimum0Maximum99999999
Default Units 
Type32 Bit VolatileUpdate RatePower-up write
Display FormatStandardDecimal Places0
CodingRO, ND, NC, PT

See Serial Number LS (MM.004).


Parameter4.00.006  Status
Short descriptionStatus
Minimum-2Maximum3
Default Units 
Type8 Bit VolatileUpdate RateBackground
Display FormatStandardDecimal Places0
CodingRO, TE, ND, NC, PT

ValueTextDescription
-2Bootldr - UpdateThe bootloader is performing a flash update
-1Bootldr - IdleThe bootloader is idle
0InitialisingInitialising
1OKModule is initialised with no errors present
2ConfigA configuration error has been detected
3ErrorAn error has occurred preventing the module from running correctly

Module Status, informs the user what state the module is in. The status is updated for bootloader state and application state.


Parameter4.00.007  Reset
Short descriptionReset
Minimum0Maximum1
Default0Units 
Type1 Bit VolatileUpdate RateRead every 200ms, Written to 0 on module initialisation
Display FormatStandardDecimal Places0
CodingRW, NC

When set the module performs a warm reset. When the reset has been performed and the module is performing its initialization routines the parameter will be cleared to zero. Note: The drive, and any other modules fitted to the drive will not be affected by the reset.


Parameter4.00.008  Default
Short descriptionDefault
Minimum0Maximum1
Default0Units 
Type1 Bit VolatileUpdate RateRead every 200ms, Written to 0 on module initialisation
Display FormatStandardDecimal Places0
CodingRW, NC

If set to “ON” when the module is reset, this parameter will cause the option module to return to its "Out of Box configuration" any settings stored on the module will be returned to their default values. This will include any Web page customisations, e-mail settings etc. Following the default the module will set the parameter to "OFF" and the module will reset.

Take care using this parameter as any configuration information will be irretrievably lost!

Note: The password for the ‘root’ account is not reset back to default.


Parameter4.00.009  Active Alarm Bits
Short descriptionCurrent Active Alarm Bits
Minimum0
(Display: 0000000000000000)
Maximum65535
(Display: 1111111111111111)
Default0
(Display: 0000000000000000)
Units 
Type16 Bit VolatileUpdate RateBackground
Display FormatBinaryDecimal Places0
CodingRO, NC, BU

Bit

Alarm

0 User Program
1 eCMP
2 Modbus
3 Ethernet/IP
4 Reserved
5 Filesystem
6 Too Hot


Parameter4.00.010  Active IP Address
Short descriptionActive IP address
Minimum-2147483648
(Display: 128.0.0.0)
Maximum2147483647
(Display: 127.255.255.255)
Default Units 
Type32 Bit VolatileUpdate RateBackground
Display FormatIP AddressDecimal Places0
CodingRO, ND, NC, PT

Modules active IP address.


Parameter4.00.011  Date Code
Short descriptionDate when first firmware updated
Minimum0Maximum65535
Default Units 
Type16 Bit VolatileUpdate RateBackground
Display FormatStandardDecimal Places0
CodingRO, ND, NC, PT, BU

Date Code (4.00.011) is a two-digit number in the form yyww where yy is the year and ww the week number.


Parameter4.00.012  Capability Mask
Short descriptionCurrent Capability Value
Minimum0
(Display: 000000000000000)
Maximum32767
(Display: 111111111111111)
Default Units 
Type16 Bit VolatileUpdate RatePower-up or reset
Display FormatBinaryDecimal Places0
CodingRO, ND, NC, PT

This is a read only value that shows the capability status of the PROFINET protocol; if the value of bit zero is 1 it indicates that the PROFINET protocol is not available; a value of zero indicates that it is available. If the user attempts to switch to the PROFINET protocol when it is not available a TRIP will be raised. This field is locked as it is determined at the point of manufacture.


Parameter4.00.013  Operation Mode
Short descriptionOperation Mode
Minimum0Maximum3
Default Units 
Type8 Bit VolatileUpdate RateBackground
Display FormatStandardDecimal Places0
CodingRO, TE, ND, NC, PT

ValueTextDescription
0NORMALIncoming cyclic data is written to the drive parameters
1LIMITED-INThe option module is transitioning from NORMAL to LIMITED mode
2LIMITEDIncoming cyclic data is not written to the drive parameters
3LIMITED-OUTThe option module is transitioning from LIMITED to NORMAL mode

Operation Mode, informs the user what operation mode the module is in. The Operation Mode is controlled by drive parameter Control Override Enable (06.086)


Parameter4.00.060  Parameter Channel Command
Short descriptionCommand for non cyclic parameter access from setup menu
Minimum0Maximum2
Default0Units 
Type8 Bit VolatileUpdate RateBackground
Display FormatStandardDecimal Places0
CodingRW, TE, NC, BU

ValueTextDescription
0NoneNo Command
1ReadRead one parameter
2WriteWrite one parameter

When a user program uses the parameter channel, writing to this parameter specifies the command, determining the operation of the channel. The table above lists the possible values and descriptions of the corresponding operations.

Setup menu non-cyclic parameter channel - overview

This feature is primarily for use by drive user programs to access parameters in the Ethernet interface. Access is provided via a non-cyclic channel created and configured using the following five parameters.

Parameter Size (bits) Description
Command (MM.060) 8 Operation of channel
Status (MM.061) 8 Status of channel (read-only)
Parameter Address (MM.062) 16 Parameter to read from or write to
Value LSW / Error Code (MM.063) 16

One of the following:

  • LSW* of Value to write (input to channel),
  • LSW* of Value read (output from channel),
  • Error Code (output from channel).
Value MSW (MM.064) 16

One of the following:

  • MSW** of Value to write (input to channel),
  • MSW** of Value read (output from channel).

*LSW: Least Significant Word (i.e. lower 16-bits of Value which is 32 bits).

**MSW: Most Significant Word (i.e. upper 16-bits of Value which is 32 bits).

 

How to use this channel

Below are two flow diagrams illustrating how to use the channel to access option module parameters.

1.      Using parameter channel to read:

2.      Using parameter channel to write:

Note that:


Parameter4.00.061  Parameter Channel Status
Short descriptionStatus of non cyclic parameter access from setup menu
Minimum0Maximum3
Default0Units 
Type8 Bit VolatileUpdate RateBackground
Display FormatStandardDecimal Places0
CodingRO, TE, NC, PT, BU

ValueTextDescription
0IdleIdle
1BusyProcessing the command.
2DoneThe command was processed successfully.
3ErrorError is detected, detail will be found in 00.063

This parameter displays the current status of the parameter channel. The table above lists the possible values and what they mean.


Parameter4.00.062  Parameter Channel Parameter Address
Short descriptionDestination or source parameter of non cyclic parameter access from setup menu S.MM.PPP
Minimum0Maximum65535
Default0Units 
Type16 Bit VolatileUpdate RateBackground
Display FormatStandardDecimal Places0
CodingRW, NC, BU

This parameter defines the parameter address required by the user program to write to or read from. It's format is equivalent to MM.PPP where the least significant 8 bits represents the parameter number, and the most significant 8 bits represents the menu number. This means that the maximum supported Menu number and parameter number will be 255 - i.e. MM.PPP = 255.255.

Note that the slot number cannot be entered as this feature is limited to only provide a channel to its own module parameter database.


Parameter4.00.063  Parameter Channel Value LSW / Error Code
Short descriptionValue (least significant word) read from or to be written to parameter channel; or error code if error is present.
Minimum-32768Maximum32767
Default0Units 
Type16 Bit VolatileUpdate RateN/A
Display FormatStandardDecimal Places0
CodingRW, NC

The data contained in this parameter depends on what command is selected and what the status is – see table below.

Command Data in parameter
Command (MM.060) = Read Least significant word of value read from parameter set in Parameter Address (MM.062).
Command (MM.060) = Write Least signficant word of value to write to parameter set in Parameter Address (MM.062).
Status (MM.061) = ERROR Error code value of the process when there is an error (see table below of error code defintions)

 

The following table lists the possible error codes:

Value

Meaning

Description

-1

Reserved


-2

Reserved

 

-3

Reserved


-4

Does not exist

The specified item does not exist.

-5

Data Type

The data could not be converted from the specified type.

-6

Reserved

The value could not be read, reason unknown.

-7

Reserved

The value could not be written, reason unknown.

-8

Not Readable

The data could not be read as the source does not allow read access.

-9

Not Writeable

The data could not be written as the destination does not allow write access.

-10

Over Range

The specified value is outside the suitable range for the item.

-11

Reserved

The request contained invalid information.

-12

Reserved

The response will not fit in the maximum response size.

-13

Decimal Place

The decimal place information is invalid (i.e. out of range of allowed values for a write).

-14

Reserved

Invalid parameter in the parameter channel.

-15

Invalid CMD

Invalid command

-16

Reserved


-17

Unknown Error

An unknown error happens

-18

64-bit access

Unsupported read/write operation on 64-bit parameter (not currently supported)

-19 to -128

Reserved


 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


Parameter4.00.064  Parameter Channel Value MSW
Short descriptionValue read from or to be written to parameter channel - most significant word.
Minimum-32768Maximum32767
Default0Units 
Type16 Bit VolatileUpdate RateN/A
Display FormatStandardDecimal Places0
CodingRW, NC

The data contained in this parameter depends on what command is selected and what the status is – see table below.

Command Data in parameter
Command (MM.060) = Read Most significant word of value read from parameter set in Parameter Address (MM.062).
Command (MM.060) = Write Most signficant word of value to write to parameter set in Parameter Address (MM.062).
Status (MM.061) = ERROR Irrelevant - error code written to MM.063.