Slot 4 Menu 0 Single Line Descriptions − Ethernet Setup

Mode: RFC‑A

ParameterRangeDefaultType
4.00.001Module ID0 to 65535  RONumNDNCPT 
4.00.002Software Version0 to 99999999  RONumNDNCPT 
4.00.003Hardware Version0.00 to 655.35  RONumNDNCPT 
4.00.004Serial Number LS00000000 to 99999999  RONumNDNCPT 
4.00.005Serial Number MS0 to 99999999  RONumNDNCPT 
4.00.006StatusBootldr ‑ Update (-2), Bootldr ‑ Idle (-1), Initialising (0), OK (1), Config (2), Error (3)  ROTxtNDNCPT 
4.00.007ResetOff (0) or On (1)Off (0)RWBit NC  
4.00.008DefaultOff (0) or On (1)Off (0)RWBit NC  
4.00.009Active Alarm Bits0000000000000000 to 1111111111111111 0000000000000000 ROBin NC  
4.00.010Active IP Address128.0.0.0 to 127.255.255.255  ROIPNDNCPT 
4.00.011Date Code0 to 65535  RONumNDNCPT 
4.00.012Capability Mask000000000000000 to 111111111111111  ROBinNDNCPT 
4.00.013Operation ModeNORMAL (0), LIMITED‑IN (1), LIMITED (2), LIMITED‑OUT (3)  ROTxtNDNCPT 
4.00.060Parameter Channel CommandNone (0), Read (1), Write (2) None (0) RWTxt NC  
4.00.061Parameter Channel StatusIdle (0), Busy (1), Done (2), Error (3) Idle (0) ROTxt NCPT 
4.00.062Parameter Channel Parameter Address0 to 65535 RWNum NC  
4.00.063Parameter Channel Value LSW / Error Code-32768 to 32767 RWNum NC  
4.00.064Parameter Channel Value MSW-32768 to 32767 RWNum NC  

RWRead / WriteRORead-onlyBitBit parameterTxtText stringDateDate parameterTimeTime parameter
ChrCharacter parameterBinBinary parameterIPIP addressMacMAC addressVerVersion numberSMPSlot, menu, parameter
NumNumber parameterDEDestinationNDNo default valueRARating dependentNCNon-copyablePTProtected
FIFilteredUSUser savePSPower-down save